Composition of MVB and WTB frame was described, and method of controlling the oscilloscope collecting the MVB or WTBdevice frame data in real time via an Ethernet by using LabVIEW program was provided. By decoding MVB or WTB device frame data in realtime, the defect which oscilloscope could not decode MVB or WTB frame data and monitor its content was recovered.