Yanyan LUO, Zhaopan ZHANG, Minmin ZHANG, et al. Research on the Change Law of Performance Parameters of Electromagnetic Relay under Vibration Condition. [J]. Electric Drive for Locomotives (4):113-117(2020)
DOI:
Yanyan LUO, Zhaopan ZHANG, Minmin ZHANG, et al. Research on the Change Law of Performance Parameters of Electromagnetic Relay under Vibration Condition. [J]. Electric Drive for Locomotives (4):113-117(2020) DOI: 10.13890/j.issn.1000-128x.2020.04.023.
Research on the Change Law of Performance Parameters of Electromagnetic Relay under Vibration Condition
Long-term vibrations often cause performance degradation or even failure of electromagnetic relays. In view of the working environment characteristics of electromagnetic relays, a vibration test scheme for electromagnetic relay was proposed. The test circuit was designed and tested. The test results showed that, when the vibration frequency is 40-130 Hz, and when the vibration acceleration increases, the release time and the bouncing time do not change signi fi cantly, the pull-in voltage decreases, the release voltage and contact resistance increase slowly, and the increase of the pick-up time and the fluctuation is the most obvious; Under the natural frequency 160 Hz, the performance parameters are obviously changed with the violent fluctuations, and the maximum fluctuation is about 2 times of other vibration conditions; Compared with the vibration frequency, the vibration acceleration has greater effect on the performance parameters. It was found that in the change of performance parameters of electromagnetic relay caused by vibration, the suction time is a more sensitive parameter.
关键词
电磁继电器振动性能参数参数检测
Keywords
electromagnetic relayvibrationperformance parameterparameter test
references
WANG G T, WANG S J, LI K. A study on the activation condition of vibration tests for particle impact noise detection of space relay remainders[C]//IEEE. 2011 6th IEEE Conference on Industrial Electronics and Applications. Beijing: IEEE, 2011: 2610-2614. DOI: 10.1109/ICIEA.2011.5976034http://doi.org/10.1109/ICIEA.2011.5976034.
WANG J, YAO F, LI Z G. Study on acquiring key performance parameters and comprehensive performance degradation model of relays[C]//IEEE. 26th International Conference on Electrical Contacts. Beijing: IEEE, 2012: 306-310. DOI: 10.1049/cp.2012.0666http://doi.org/10.1049/cp.2012.0666.
REN W B, LIANG H M, CHEN Y H, et al. Mechanical and electrical characteristics of the electromagnetic relay under vibration and shock environment[C]//IEEE. 2009 Proceedings of the 55th IEEE Holm Conference on Electrical Contacts. Vancouver: IEEE,2009: 42-48. DOI: 10.1109/HOLM.2009.5284425http://doi.org/10.1109/HOLM.2009.5284425.
MIYANAGA K, MATSUMOTO S, TAKAHASHI K, et al. A study on growth of dust of needle-like crystal from a flame retarder of electromagnetic relay housing[C]//IEEE. 2018 IEEE Holm Conference on Electrical Contacts. Albuquerque: IEEE, 2018: 516-520. DOI: 10.1109/HOLM.2018.8611773http://doi.org/10.1109/HOLM.2018.8611773.
ZHAI G F, CHEN Y H, REN W B. Analyzing method of random vibration characteristic for armature system of hermetically sealed electromagnetic relay[C]//IEEE. Electrical Contacts - 2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts. Pittsburgh: IEEE, 2007: 183-187. DOI: 10.1109/HOLM.2007.4318214http://doi.org/10.1109/HOLM.2007.4318214.
LAMBRECHT N, PUES H, DE ZUTTER D, et al. Modeling of contact bounce in a transient electromagnetic compatibility test for the analysis and optimization of nonlinear devices[J]. IEEE Transactions on Electromagnetic Compatibility, 2017, 59(2): 541-544.