HAO Qi, FENG Xiao-yun. Research on Minimum Switch Loss Modulation Strategy of ANPC. [J]. Electric Drive for Locomotives (4):24-27(2014)
DOI:
HAO Qi, FENG Xiao-yun. Research on Minimum Switch Loss Modulation Strategy of ANPC. [J]. Electric Drive for Locomotives (4):24-27(2014) DOI: 10.13890/j.issn.1000-128x.2014.04.007.
Research on Minimum Switch Loss Modulation Strategy of ANPC
A new modulation scheme for reducing switching loss was introduced for three-level active neutral-point-clamped (ANPC) inverter topology. The loss in each switch state was analyzed qualitatively; based on zero-order injection carrier-modulation method, a dynamic minimum switching loss modulation scheme was proposed; Simulation model was built to test and verify the applicability of this scheme in controlling the CRH380A EMUs motor and resistance-inductance load. The results showed that this topology modulation scheme reduced the total switching loss, balanced the loss distribution and efficiently improved the thermal stability of traction system.