Effects of Flow Regime and Heat Source Simplifications on Simulation Results for Water-Cooling Plate of IGBT. [J]. Electric Drive for Locomotives (5):21-25(2011)
DOI:
Effects of Flow Regime and Heat Source Simplifications on Simulation Results for Water-Cooling Plate of IGBT. [J]. Electric Drive for Locomotives (5):21-25(2011) DOI: 10.13890/j.issn.1000-128x.2011.05.010.
Effects of Flow Regime and Heat Source Simplifications on Simulation Results for Water-Cooling Plate of IGBT
By comparing laminar and turbulent models, the flow regime of water-cooling plate with straight channels was researched; the results showed that the average velocities were different in channels, and it was improper to set the flow regime of all channels with laminar or turbulent. The highest different temperature of IGBT installing place of water-cooling plate would be 6~9 ℃ to IGBT precise model compared with uniform layout heat source. The exact temperature field and junction temperature of IGBT would be got with precise model, which helped optimizing channel structure and improving heat transfer efficiency.
关键词
IGBT水冷板流动状态热源水冷散热器主变流器仿真结果
Keywords
IGBTwater-cooling plateflow regimeheat sourcewater-cooling radiatorpower convertersimulation result