Effect Analysis of Operation Condition and Environment on High-speed Train Device Ventilation. [J]. Electric Drive for Locomotives (4):11-13(2011)
DOI:
Effect Analysis of Operation Condition and Environment on High-speed Train Device Ventilation. [J]. Electric Drive for Locomotives (4):11-13(2011) DOI: 10.13890/j.issn.1000-128x.2011.04.008.
Effect Analysis of Operation Condition and Environment on High-speed Train Device Ventilation
Impact factors of different speed, operation environment to high-speed train device ventilation were studied and analyzed. The result shows that speed and environment temperature have few effects to device ventilation. Operation in tunnel causes device ventilation rate slight decreasing, and humidity influences pressure head and power of ventilation.